INP_SELX=PWM_X, ARMX=DISABLED, EDGX1=DISABLED, EDGX0=DISABLED, EDGCNTX_EN=DISABLED, ONESHOTX=FREE_RUNNING
Capture Control X Register
ARMX | Arm X 0 (DISABLED): Input capture operation is disabled. 1 (ENABLED): Input capture operation as specified by CAPTCTRLX[EDGXx] is enabled. |
ONESHOTX | One Shot Mode Aux 0 (FREE_RUNNING): Free Running 1 (ONE_SHOT): One Shot |
EDGX0 | Edge X 0 0 (DISABLED): Disabled 1 (FALLING_EDGE): Capture falling edges 2 (RISING_EDGE): Capture rising edges 3 (ANY_EDGE): Capture any edge |
EDGX1 | Edge X 1 0 (DISABLED): Disabled 1 (FALLING_EDGE): Capture falling edges 2 (RISING_EDGE): Capture rising edges 3 (ANY_EDGE): Capture any edge |
INP_SELX | Input Select X 0 (PWM_X): Raw PWM_X input signal selected as source. 1 (EDGE_COUNTER): Edge Counter |
EDGCNTX_EN | Edge Counter X Enable 0 (DISABLED): Edge counter disabled and held in reset 1 (ENABLED): Edge counter enabled |
CFXWM | Capture X FIFOs Water Mark |
CX0CNT | Capture X0 FIFO Word Count |
CX1CNT | Capture X1 FIFO Word Count |